crusher gradient resonance

Crusher Gradient Resonance

crusher gradient followedcrusher gradient resonance

Crusher Gradients • Crusher Gradients: is a correction gradient that preserves the desired signal pathways while eliminating unwanted ones by manipulating the phase of the signals. • Consists of two lobes with the same polarity immediately before and after the …

Pathway selection by pulsed field gradients - Rodriguez ...

Abstract A method for pathway selection in a multiple spin‐echo pulse sequence applying crusher gradients before and after each π pulse, to dephase unwanted pathways, is …

Correction Gradients - 81Bones.net

Crusher Gradients • Crusher Gradients: is a correction gradient that preserves the desired signal pathways while eliminating unwanted ones by manipulating the phase of the signals. • Consists of two lobes with the same polarity immediately before and after the …

Lipid suppression for brain MRI and MRSI by means of a ...

All techniques require additional RF pulses, gradient crushers and delays, which increase the duration and complexity of sequences. In addition, the lipid signal is poorly shimmed, and is composed of different resonance frequencies that have different relaxation properties.

Home | MR SCIENCE Laboratory

Novel Gradient Crusher Optimization Scheme Published in MRM The MR SCIENCE lab has published a novel algorithm, referred to as Dephasing Optimization Through Coherence Order Pathway Selection (DOTCOPS), which designs crusher schemes for any magnetic resonance spectroscopy experiment, and can be used for any metabolite of interest.

Extended Phase Graphs (EPG) - Stanford University

EPG Propagation: Gradient n Mx My F 0 Mx My F-1 Mx My F 1 Mx My F-2 • Magnetization in F n moves to F n+1 –Dephasing for n>=0 –Rephasing for n<0 •Generally can apply p cycles (increase n by p) • Z states are unaffected Assume the “gradient” such as a spoiler or crusher induces one twist cycle per voxel F n+1 = F n Gradients induce ...

Magnetic Resonance Imaging with Composite (Dual) Gradients

Apr 01, 2009 · The expected reduction is most evident for high resolution where the imaging gradients have a greater amplitude (area) relative to the spoiler and crusher gradients. Using composite gradients (ESP of body gradients at 0.6mm isotropic voxels) yields a 35% reduction in ESP over that of the body gradients for 0.2mm isotropic voxels.

Optimal control of the signal-to-noise ratio per unit time ...

Optimal control of the signal-to-noise ratio per unit time of a spin 1/2 particle: The crusher gradient and the radiation damping cases M. Lapert, E. Assémat, S. J. Glaser, and D. Sugny

Correction for vascular artifacts in cerebral blood flow ...

crusher gradient was set to zero, and a “fat saturation” pulse, consisting of a 16-ms nonselective sinc pulse fol- lowed by gradient spoiler pulses, was added to the se- quence. The z gradient was not turned on during the irradia- tion. In the absence of a z gradient, the off-resonance RF

Pulsed field gradient - Wikipedia

Pulsed field gradient. A pulsed field gradient is a short, timed pulse with spatial-dependent field intensity. Any gradient is identified by four characteristics: axis, strength, shape and duration. Pulsed field gradient (PFG) techniques are key to magnetic resonance imaging, spatially selective spectroscopy and studies of diffusion via diffusion...

Parallel ImagingYBased Reduction of Acoustic Noise for ...

taining a similar crusher moment. Assuming a fixed total acquisition time, the reduction of the gradient slew rate is constrained by the fixed inter-echo spacing. Therefore, the first approach to further reduce the gradient slew rate was to reduce the readout sampling time, as illus-tratedinFigure1.ThisresultsinaslightincreaseinBWand,therefore,

Tracking the effects of crusher gradients on gradient-echo ...

A unique method to map the effect of crusher gradients in space and time on the gradient echo BOLD signal is introduced. Using the Radial Correlation Contrast (RCC) analysis method, amplitude-RCC maps at different time segments and different gradient strengths were obtained.

Magnetism - Questions and Answers in MRI

A crusher gradient (G) is typically applied immediately after the pulse to destroy transverse coherences. After being tipped into the transverse plane tissues begin to recover longitudinal magnetization as a function of their T1 values.

1288 - Mira Smart Conferencing

In a magnetic resonance spectroscopy (MRS) pulse sequence a scheme of pulsed magnetic field gradient "crushers" are played out during times in-between radiofrequency (RF) pulses to dephase unwanted coherence pathways which are incidentally perturbed by the RF pulses.

Magnetic Resonance Imaging - Penn Math

Magnetic Resonance Imaging Charles L. Epstein Introduction Diffusion Magnetic Susceptibility Acknow-ledgments Diffusion Imaging At finite, non-zero temperatures, water molecules are in continual motion. The extent of these motions is a reflection of the local physical environment. The first phenomenon we consider is connected to the ...

Spin-Echo Sequences - Stanford University

Relaxation and crusher gradient 3. ... •Slice-selective pulses are off-resonance to others •MT saturation effect - suppresses some signals ... B.Hargreaves - RAD 229 Spin-Echo Sequences •Basic spin echo •Echo-trains: RARE, FSE, TSE •Efficient T2 and PD contrast •Extreme cases: SSFSE/HASTE •3D Echo trains •Signal considerations

Optimal control of the signal-to-noise ratio per unit time ...

In the periodic regime, the objective of the control problem is to design the initial state of the system and the pulse sequence which leads to the best signal to noise performance. We focus on two specific issues relevant in nuclear magnetic resonance, the crusher gradient and the radiation damping cases.

11-01 - Magnetic resonance imaging

Usually a chemical-shift selective pulse sequence (CHESS) or a variation of this sequence is used. With a frequency-selective 90º pulse, the magnetization of fat is rotated into the transverse plane where its dephasing is accelerated by a spoiler (or crusher) gradient.

Slice profile optimization in arterial spin labeling using ...

Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses David Alberg Holma,b,4, Karam Sidarosa aDanish Research Centre for Magnetic Resonance, Copenhagen University Hospital, 2650 Hvidovre, Denmark bInformatics and Mathematical Modelling, Technical University of Denmark, 2800 Lyngby, Denmark Received 4 November 2005; accepted 2 July 2006